Surge Protection
Lightning, Spike, and Transient Surge Protection
Most surge protectors will allow a momentary spike before capping the power. Our Clean-Volt equipment is electronically controlled and will never allow a surge to pass into your equipment in the first place.
Protection
Clean-Volt gives you the serious protection you require from lightning, accidental utility supply events (Car hitting an electrical pole) and any electrical anomalies created within your own electrical system.
Appliance and Equipment Life
Clean-Volt provides an environment for your equipment and appliances that allow them to reach the manufactures suggested life expectancy on items ranging from your t.v to your refrigerator to your light bulbs.
Power Supply
Clean-Volt allows your electrical system to operate at maximum efficiency by taking out the unnecessary resistance so your equipment and appliances will run cooler and more efficiently.
- Reduction in peak demand
- Increase lifespan of your equipment and lighting
- Reduced maintenance and operating cost
- Reduced kilowatt consumption
- Lifetime (100 year) warranty
Certifications and Technical Specifications
Product Table 1
Model | CV1 | CV2 | CVS 120V |
CVS 240V |
CV4 | CV6 |
---|---|---|---|---|---|---|
Electrical Specifications | ||||||
Voltage and Phase | 120/240V 1 Phase |
120/208V 3 Phases |
120V 1 Phase |
240V 1 Phase |
347/600V WYE 3 Phases, 4 Wire |
600V Delta 3 Phases, 3 Wire |
Max Panel Rating | Up to 600 Amps |
Up to 600 Amps |
Up to 600 Amps |
Up to 600 Amps |
Up to 600 Amps |
Up to 600 Amps |
Nominal Discharge Rating (In) | N/A | N/A | N/A | N/A | N/A | N/A |
Response time with 6-inch lead | <1 NS | <1 NS | <1 NS | <1 NS | <1 NS | <1 NS |
Claming Voltage | 132/250V | 132/230V | 132V | 250V | 395/690V | 710V |
Discharge Capacity 1 Phase to Neutral/Ground 8x20 Micro Second Pulse |
10,000 A | 10,000 A | 10,000 A | 10,000 A | 30,000 A | 30,000 A |
Standards and Certifications | ||||||
Agency Certification | ||||||
CSA Standard | ||||||
ANSI/IEEE Category | ||||||
Flammability | ||||||
Size | 2.75 x 4.0 x 2.5" | 3.0 x 4.5 x 4.75" | 2.75 x 4.0 x 2.5" | 2.75 x 4.0 x 2.5" | 3 boxes of 2.75 x 4.0 x 2.5" |
3 boxes of 2.75 x 4.0 x 2.5" |
Weight | 3.5 lb | 7.75 lb | 3.5 lb | 3.5 lb | 11 lb | 11 lb |
Recommended Breaker Ka Rating *Same or greater than main over current. |
2-pole 20 A |
3-pole 20 A |
1-pole 20 A |
1-pole 20 A |
3-pole 30 A |
3-pole 30 A |
Warranty | ||||||
Product Warranty | ||||||
Connected Equipement | ||||||
Certifications and Technical Specifications
Product Table 2
Product | CV3 | CV5-3 | CV7-4 | CV8 | CVR Residential | |
---|---|---|---|---|---|---|
Electrical Specifications | ||||||
Voltage and phase | 277/480V 3 Phase |
240V 3 Phases Delta |
480V 3 phases Delta |
120/208V 3 Phases Delta |
120/240V Residential |
|
Current | Up to 3000 Amps |
Up to 1000 Amps |
Up to 3000 Amps |
Up to 1000 Amps |
Up to 400 Amps |
|
Nominal Discharge Rating (In) | N/A | N/A | N/A | N/A | N/A | |
Response time with 6-inch lead | <1 NS | <1 NS | <1 NS | <1 NS | <1 NS | |
Clamping Voltage | 320/510V | 275V | 575V | 132/250V | 132/250V | |
Discharge Capacity 1 Phase to Neutral/Ground 8x20 Micro Second Pulse |
30,000 A | 20,000 A | 30,000 A | 20,000 A | 10,000 A | |
Standards and Certifications | ||||||
Agency Certification | ||||||
CSA Standard | ||||||
ANSI/IEEE Category | ||||||
Flammability | ||||||
Size | 3 boxes of 2.75 x 4.0 x 2.5" |
3.0 x 4.5 x 4.75" | 3 boxes of 2.75 x 4.0 x 2.5" |
3.0 x 4.5 x 4.75" | 2.75 x 4.0 x 2.5" | |
Weight | 11 lb | 7.75 lb | 11 lb | 7.75 lb | 3.5 lb | |
Recommended Breaker Ka Rating *Same or greater than main over current. |
3-pole 30 A |
3-pole 20 A |
3-pole 30 A |
3-pole 20 A |
2-pole 20 A |
|
Warranty | ||||||
Product Warranty | ||||||
Connected Equipement |